ITAC Assessment: MI0145
ITAC logo
ITAC Assessment: MI0145
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2007
Principal Product Electrical Relays and Switches
NAICS 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial
SIC 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products
Sales Range $10
M
to 50
M
# of Employees 108
Plant Area 75,000
ft2
Annual Production 100,000
pieces
Production Hrs. Annual 2,475
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $137,738 1,761,360
kWh
Electricity Demand $31,634 4,598
kW-mo/yr
Electricity Fees $22,972 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,291 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $59,530

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7221: Lower temperature during the winter season and vice-versa $26,104 $915 $23,297
297,919
kWh
$2,807
-
kW-mo/yr
02 2.7142: Utilize higher efficiency lamps and/or ballasts $32,164 $45,864 $25,673
245,308
kWh
$6,491
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,811 $1,074 $2,382
30,473
kWh
$429
-
kW-mo/yr
04 2.4323: Use optimum size and capacity equipment $2,005 $3,400 $1,533
19,598
kWh
$472
-
kW-mo/yr
05 2.7447: Install vinyl strip / high speed / air curtain doors $1,120 $1,175 $1,120
10,103
kWh
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $945 $30 $711
9,093
kWh
$234
-
kW-mo/yr
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $142 $225 $142
1,689
kWh
-
TOTAL RECOMMENDED $65,291 $52,683 $54,858
614,183
kWh
$10,433
-
kW-mo/yr
TOTAL IMPLEMENTED $59,530 $48,179 $50,232
555,019
kWh
$9,298
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs