ITAC Assessment: MI0122
ITAC logo
ITAC Assessment: MI0122
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2006
Principal Product Wooden Doors, Kitchen Cabinets
NAICS 321911: Wood Window and Door Manufacturing
SIC 2431: Millwork
Sales Range $10
M
to 50
M
# of Employees 129
Plant Area 86,000
ft2
Annual Production 80,000
pieces
Production Hrs. Annual 2,200
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $58,528 1,051,860
kWh
Electricity Demand $38,833 4,930
kW-mo/yr
Electricity Fees $12,163 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $47,477 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4323: Use optimum size and capacity equipment $18,965 $5,163 $10,574
190,106
kWh
$8,391
-
kW-mo/yr
02 2.4323: Use optimum size and capacity equipment $15,874 $3,709 $7,182
129,116
kWh
$8,692
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,318 $1,074 $3,273
58,843
kWh
$2,045
-
kW-mo/yr
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,569 $1,074 $2,214
39,808
kWh
$1,355
-
kW-mo/yr
05 2.4321: Upgrade obsolete equipment $1,134 $28 $599
10,773
kWh
$535
-
kW-mo/yr
06 2.4321: Upgrade obsolete equipment $1,085 $28 $540
10,773
kWh
$545
-
kW-mo/yr
07 2.4221: Install compressor air intakes in coolest locations $685 $260 $405
7,256
kWh
$280
-
kW-mo/yr
08 2.4323: Use optimum size and capacity equipment $602 $940 $334
6,012
kWh
$268
-
kW-mo/yr
09 2.4323: Use optimum size and capacity equipment $245 $940 $134
2,416
kWh
$111
-
kW-mo/yr
TOTAL RECOMMENDED $47,477 $13,216 $25,255
455,103
kWh
$22,222
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs