Assessment Year | 2005 |
---|---|
Principal Product | Metal Lockers |
NAICS | 337215: Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 2542: Office and Store Fixtures, Partitions, Shelving, and Lockers, Except Wood |
Sales Range | $10 M to 50M |
# of Employees | 270 |
Plant Area |
100,000
ft2
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 5,900
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $224,493 | 4,424,160 |
kWh
|
$0.051 |
Electricity Demand | $92,043 | 11,164 |
kW-mo/yr
|
$8.24 |
Electricity Fees | $21,984 | - |
|
- |
Natural Gas | $296,818 | 42,403 |
MMBtu
|
$7.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $148,212 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $110,009 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $94,802 | $420 |
$3,388
66,778
kWh
|
$1,414
-
kW-mo/yr
|
- | $90,000 | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $33,460 | $2,314 | - | - |
$33,460
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,435 | $1,074 |
$8,444
166,419
kWh
|
$1,991
-
kW-mo/yr
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,743 | $4,732 |
$3,209
63,244
kWh
|
$1,534
-
kW-mo/yr
|
- | - | |
05 | 2.4323: Use optimum size and capacity equipment | $2,775 | $6,660 |
$2,134
42,062
kWh
|
$641
-
kW-mo/yr
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,997 | - |
$1,363
26,856
kWh
|
$634
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $148,212 | $15,200 |
$18,538
365,359
kWh
|
$6,214
-
kW-mo/yr
|
$33,460
-
MMBtu
|
$90,000 | ||
TOTAL IMPLEMENTED | $110,009 | $8,154 |
$15,329
302,115
kWh
|
$4,680
-
kW-mo/yr
|
- | $90,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs