| Assessment Year | 2005 |
|---|---|
| Principal Product | Plastic Bottle Manufacturing |
| NAICS | 326160: Plastics Bottle Manufacturing |
| SIC | 3085: Plastics Bottles |
| Sales Range | $10 M to 50M |
| # of Employees | 60 |
| Plant Area |
45,000
ft2
|
| Annual Production | 20,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $71,937 | 1,367,422 |
kWh
|
$0.053 |
| Electricity Demand | $42,950 | 5,743 |
kW-mo/yr
|
$7.48 |
| Electricity Fees | $17,633 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,878 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,878 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $6,164 | $10,917 |
$6,164
103,832
kWh
|
- | - | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,621 | $56 |
$3,521
70,417
kWh
|
$1,100
-
kW-mo/yr
|
- | - | |
| 03 | 2.8114: Change rate schedules or other changes in utility service | $3,664 | $600 | - | - | - | $3,664 | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,993 | $870 |
$2,473
32,618
kWh
|
- | $(-480.0) | - | |
| 05 | 2.6231: Utilize controls to operate equipment only when needed | $1,436 | $200 |
$1,436
26,100
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $17,878 | $12,643 |
$13,594
232,967
kWh
|
$1,100
-
kW-mo/yr
|
$(-480.0) | $3,664 | ||
| TOTAL IMPLEMENTED | $17,878 | $12,643 |
$13,594
232,967
kWh
|
$1,100
-
kW-mo/yr
|
$(-480.0) | $3,664 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs