Assessment Year | 2004 |
---|---|
Principal Product | Lumber, pre-fabricated roof truss, fabricated rebar’s |
NAICS | 321912: Cut Stock, Resawing Lumber, and Planing |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 190 |
Plant Area |
522,720
ft2
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,940 | 1,158,900 |
kWh
|
$0.051 |
Electricity Demand | $26,504 | 3,608 |
kW-mo/yr
|
$7.35 |
Electricity Fees | $16,878 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $231,900 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $230,698 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Primary Product Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $21,868 | $2,300 |
$21,868
368,341
kWh
|
- | |
02 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $197,433 | $74,805 |
$570
9,763
kWh
|
$196,863 | |
03 | 2.6218: Turn off equipment when not in use | $175 | - |
$175
3,513
kWh
|
- | |
04 | 2.4131: Size electric motors for peak operating efficiency | $11,397 | $5,248 |
$847
16,092
kWh
|
$10,550 | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,027 | - |
$1,027
19,241
kWh
|
- | |
TOTAL RECOMMENDED | $231,900 | $82,353 |
$24,487
416,950
kWh
|
$207,413 | ||
TOTAL IMPLEMENTED | $230,698 | $82,353 |
$23,285
394,196
kWh
|
$207,413 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs