Assessment Year | 2002 |
---|---|
Principal Product | Corrugated Products |
NAICS |
n/a
|
SIC | 2654: |
Sales Range | $10 M to 50M |
# of Employees | 52 |
Plant Area |
65,000
ft2
|
Annual Production | 180,000,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,021 | 682,878 |
kWh
|
$0.063 |
Electricity Demand | $14,713 | 1,932 |
kW-mo/yr
|
$7.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $165,224 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $154,448 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,448 | $1,859 | - |
$4,448
-
kW-mo/yr
|
- | - | |
02 | 2.7212: Install or upgrade insulation on hvac distribution systems | $1,410 | $2,000 |
$1,410
22,384
kWh
|
- | - | - | |
03 | 4.454: Modify startup/shutdown times | $150,000 | $3,900 | - | - | - | $150,000 | |
04 | 3.5131: Recycle white water | $2,639 | $982 | - | - |
$2,639
-
Tgal
|
- | |
05 | 2.4323: Use optimum size and capacity equipment | $6,727 | $1,250 |
$4,904
77,834
kWh
|
$1,823
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $165,224 | $9,991 |
$6,314
100,218
kWh
|
$6,271
-
kW-mo/yr
|
$2,639
-
Tgal
|
$150,000 | ||
TOTAL IMPLEMENTED | $154,448 | $5,759 | - |
$4,448
-
kW-mo/yr
|
- | $150,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs