ITAC Assessment: ME0272
ITAC logo
ITAC Assessment: ME0272
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product Packaging
NAICS
n/a
SIC 3082: Unsupported Plastics Profile Shapes
Sales Range $10
M
to 50
M
# of Employees 240
Plant Area 55,000
ft2
Annual Production 15,120,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) Maine

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $492,245 7,575,323
kWh
Electricity Demand $111,600 17,885
kW-mo/yr
LPG $46,007 8,009
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $88,086 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,836

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings One-time Revenue or Avoided Cost Savings
01 2.2711: Utilize outside air instead of conditioned air for drying $19,520 $4,860 $19,520
300,410
kWh
- - -
02 2.2437: Recover waste heat from equipment $11,434 $2,159 - - $11,434
-
MMBtu
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $12,056 $22,438 $10,461
160,903
kWh
$1,595
-
kW-mo/yr
- -
04 2.4239: Eliminate or reduce compressed air usage $9,306 $450 $9,306
143,318
kWh
- - -
05 2.4239: Eliminate or reduce compressed air usage $9,306 $500 $9,306
143,318
kWh
- - -
06 2.4221: Install compressor air intakes in coolest locations $9,227 $850 $9,227
142,732
kWh
- - -
07 4.821: Pay bills on time to avoid late fees $5,265 - - - - $5,265
08 2.1311: Replace electrically-operated equipment with fossil fuel equipment $5,172 $5,760 $4,964
76,202
kWh
$2,021
-
kW-mo/yr
$(-1,813.0)
-
MMBtu
-
09 2.4133: Use most efficient type of electric motors $2,760 $7,122 $2,438
37,515
kWh
$322
-
kW-mo/yr
- -
10 2.1311: Replace electrically-operated equipment with fossil fuel equipment $2,141 $7,579 $1,909
26,377
kWh
$823
-
kW-mo/yr
$(-591.0)
-
MMBtu
-
11 2.2511: Insulate bare equipment $1,899 $1,260 - - $1,899
-
MMBtu
-
TOTAL RECOMMENDED $88,086 $52,978 $67,131
1,030,775
kWh
$4,761
-
kW-mo/yr
$10,929
-
MMBtu
$5,265
TOTAL IMPLEMENTED $35,836 $16,751 $16,708
257,035
kWh
$2,343
-
kW-mo/yr
$11,520
-
MMBtu
$5,265
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs