| Assessment Year | 1998 |
|---|---|
| Principal Product | ball valves and actuators |
| NAICS |
n/a
|
| SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 45 |
| Plant Area |
87,500
ft2
|
| Annual Production | 100,000
pieces
|
| Production Hrs. Annual | 4,125
hrs
|
| Location (State) | New Hampshire |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $69,746 | 565,944 |
kWh
|
$0.12 |
| Electricity Demand | $16,719 | 2,022 |
kW-mo/yr
|
$8.27 |
| LPG | $17,919 | 2,531 |
MMBtu
|
$7.08 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $26,969 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (haz) Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,883 | $25,900 | n/a |
$6,973
77,374
kWh
|
$1,910
-
kW-mo/yr
|
- | - | - |
| 02 | 2.4133: Use most efficient type of electric motors | $1,601 | $14,083 | n/a |
$986
10,844
kWh
|
$615
-
kW-mo/yr
|
- | - | - |
| 03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,320 | $2,600 | n/a |
$578
4,689
kWh
|
$893
-
kW-mo/yr
|
$(-151.0)
-
MMBtu
|
- | - |
| 04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $911 | $450 | n/a |
$881
9,672
kWh
|
$446
-
kW-mo/yr
|
$(-416.0)
-
MMBtu
|
- | - |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $830 | $500 | n/a |
$830
9,086
kWh
|
- | - | - | - |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $304 | $300 | n/a |
$304
3,224
kWh
|
- | - | - | - |
| 07 | 3.3131: Use evaporation to concentrate material | $6,872 | $17,050 | n/a | - | - |
$(-1,295.0)
-
MMBtu
|
$8,167
-
gal
|
- |
| 08 | 3.3133: Use other waste concentration methods | $6,248 | $6,950 | n/a | - | - | - | - | $6,248 |
| TOTAL RECOMMENDED | $26,969 | $67,833 |
$10,552
114,889
kWh
|
$3,864
-
kW-mo/yr
|
$(-1,862.0)
-
MMBtu
|
$8,167
-
gal
|
$6,248 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (haz) Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs