Assessment Year | 1998 |
---|---|
Principal Product | Modified Food Starch |
NAICS |
n/a
|
SIC | 2046: Wet Corn Milling |
Sales Range | $10 M to 50M |
# of Employees | 68 |
Plant Area |
63,265
ft2
|
Annual Production | 36,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $365,388 | 6,065,944 |
kWh
|
$0.060 |
Electricity Demand | $88,615 | 10,987 |
kW-mo/yr
|
$8.07 |
Electricity Fees | $2,084 | - |
|
- |
Fuel Oil #2 | $33,326 | 6,288 |
MMBtu
|
$5.30 |
Fuel Oil #6 | $122,527 | 30,069 |
MMBtu
|
$4.07 |
Wood | $88,377 | 31,145 |
MMBtu
|
$2.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,826 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Fuel Oil #6 Savings | Wood Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $20,829 | $46,000 | - | - | - |
$20,829
-
MMBtu
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $6,526 | $27,594 |
$5,311
88,511
kWh
|
$1,215
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,300 | $18,666 |
$5,320
88,804
kWh
|
$980
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $2,349 | $400 |
$2,349
39,273
kWh
|
- | - | - | - | - | |
05 | 2.2511: Insulate bare equipment | $830 | $231 |
$277
3,810
kWh
|
- |
$87
-
MMBtu
|
$466
-
MMBtu
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $709 | $1,406 |
$709
11,723
kWh
|
- | - | - | - | - | |
07 | 2.2511: Insulate bare equipment | $276 | $29 |
$276
4,689
kWh
|
- | - | - | - | - | |
08 | 3.4151: Minimize water usage | $3,051 | $273 | - | - | - | - | - |
$3,051
-
Tgal
|
|
09 | 3.4151: Minimize water usage | $1,758 | $3,702 |
$288
(-4,689)
kWh
|
- | - |
$492
-
MMBtu
|
$495
-
MMBtu
|
$483
-
Tgal
|
|
TOTAL RECOMMENDED | $42,628 | $98,301 |
$14,530
232,121
kWh
|
$2,195
-
kW-mo/yr
|
$87
-
MMBtu
|
$21,787
-
MMBtu
|
$495
-
MMBtu
|
$3,534
-
Tgal
|
||
TOTAL IMPLEMENTED | $12,826 | $46,260 |
$10,631
177,315
kWh
|
$2,195
-
kW-mo/yr
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings | Fuel Oil #6 Savings | Wood Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs