ITAC Assessment: NV0163
ITAC logo
ITAC Assessment: NV0163
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2000
Principal Product industrial inorganic chemicals
NAICS
n/a
SIC 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 84
Plant Area 74,500
ft2
Annual Production 75,400
lb
Production Hrs. Annual 8,760
hrs
Location (State) Nevada

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $472,398 11,507,000
kWh
Electricity Demand $216,089 23,080
kW-mo/yr
Natural Gas $1,487,688 517,572
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $162,500 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
01 2.4133: Use most efficient type of electric motors $2,021 $2,398 n/a $1,536
38,394
kWh
$485
-
kW-mo/yr
-
02 2.7132: Install timers on light switches in little used areas $1,105 $675 n/a $1,105
27,550
kWh
- -
03 3.4154: Eliminate leaks in water lines and valves $3,756 - n/a $3,756
75,322
kWh
- -
04 4.441: Install automatic packing equipment $106,434 $41,000 n/a - - $106,434
05 2.4321: Upgrade obsolete equipment $49,184 $25,969 n/a $9,824
272,274
kWh
- $39,360
TOTAL RECOMMENDED $162,500 $70,042 $16,221
413,540
kWh
$485
-
kW-mo/yr
$145,794
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs