| Assessment Year | 1997 |
|---|---|
| Principal Product | Woolen Greige Goods |
| NAICS |
n/a
|
| SIC | 2231: Broadwoven Fabric Mills, Wool (Including Dyeing and Finishing) |
| Sales Range | $1 M to 5M |
| # of Employees | 225 |
| Plant Area |
140,000
ft2
|
| Annual Production | 67,500
thousand feet
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | Maine |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $658,573 | 9,739,742 |
kWh
|
$0.068 |
| Electricity Demand | $216,187 | 21,029 |
kW-mo/yr
|
$10.28 |
| Electricity Fees | $18,596 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $68,474 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $46,079 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $20,315 | $6,070 |
$20,315
225,967
kWh
|
- | - | - | - | |
| 02 | 2.3511: Use plant owned transformers or lease transformers | $10,587 | $19,335 | - | - | - | - | $10,587 | |
| 03 | 2.4133: Use most efficient type of electric motors | $7,808 | $23,664 |
$7,672
107,562
kWh
|
$136
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,873 | $3,846 |
$4,873
69,754
kWh
|
- | - | - | - | |
| 05 | 3.7121: Improve handling practices | $2,190 | $500 | - | - | - | - | $2,190 | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $2,084 | $480 |
$2,084
29,894
kWh
|
- | - | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,148 | $2,360 |
$983
11,723
kWh
|
$165
-
kW-mo/yr
|
- | - | - | |
| 08 | 3.4115: Recover and reuse cooling water | $17,389 | $6,500 | - | - |
$17,389
-
Tgal
|
- | - | |
| 09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,080 | $10,200 | - | - | - |
$2,080
-
lb
|
- | |
| TOTAL RECOMMENDED | $68,474 | $72,955 |
$35,927
444,900
kWh
|
$301
-
kW-mo/yr
|
$17,389
-
Tgal
|
$2,080
-
lb
|
$12,777 | ||
| TOTAL IMPLEMENTED | $46,079 | $56,685 |
$15,612
218,933
kWh
|
$301
-
kW-mo/yr
|
$17,389
-
Tgal
|
- | $12,777 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs