Assessment Year | 1997 |
---|---|
Principal Product | Composite Materials |
NAICS |
n/a
|
SIC | 2221: Broadwoven Fabric Mills, Manmade Fiber and Silk |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
50,000
ft2
|
Annual Production | 16,000,000
lb
|
Production Hrs. Annual | 7,696
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,452 | 819,754 |
kWh
|
$0.079 |
Electricity Demand | $16,005 | 2,014 |
kW-mo/yr
|
$7.95 |
Electricity Fees | $3,399 | - |
|
- |
LPG | $13,679 | 1,704 |
MMBtu
|
$8.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,716 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,675 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,030 | $600 |
$3,030
43,376
kWh
|
- | - | - | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,766 | $20 |
$2,766
39,566
kWh
|
- | - | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,949 | $3,274 |
$1,949
27,843
kWh
|
- | - | - | - | - | |
04 | 2.8123: Pay utility bills on time | $1,220 | - | - | - | - | - | $1,220 | - | |
05 | 2.2515: Use optimum thickness insulation | $788 | $290 |
$788
11,137
kWh
|
- | - | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $738 | $200 |
$738
10,551
kWh
|
- | - | - | - | - | |
07 | 2.8121: Apply for tax-free status for energy purchases | $452 | - | - | - | - | - | $452 | - | |
08 | 2.5195: Change product design to reduce energy requirements | $354 | - |
$217
2,931
kWh
|
$137
-
kW-mo/yr
|
- | - | - | - | |
09 | 4.211: Consider use / purchase of bulk materials where possible | $24,276 | $6,900 | - | - | - |
$131
-
lb
|
- | $24,145 | |
10 | 3.4116: Meter recycled water (to reduce sewer charges) | $143 | $400 | - | - |
$143
-
Tgal
|
- | - | - | |
TOTAL RECOMMENDED | $35,716 | $11,684 |
$9,488
135,404
kWh
|
$137
-
kW-mo/yr
|
$143
-
Tgal
|
$131
-
lb
|
$1,672 | $24,145 | ||
TOTAL IMPLEMENTED | $32,675 | $8,210 |
$6,584
94,079
kWh
|
- |
$143
-
Tgal
|
$131
-
lb
|
$1,672 | $24,145 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs