ITAC Assessment: AM0596
ITAC logo
ITAC Assessment: AM0596
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2011
Principal Product Multiplex machines
NAICS 339112: Surgical and Medical Instrument Manufacturing
SIC 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies
Sales Range $100
M
to 500
M
# of Employees 300
Plant Area 32,000
ft2
Annual Production 900
pieces
Production Hrs. Annual 3,120
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $162,254 3,018,495
kWh
Electricity Demand $95,113 7,238
kW-mo/yr
Electricity Fees $14,946 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $35,515 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,515

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $35,020 - - - $7,020 - $28,000
02 2.7142: Utilize higher efficiency lamps and/or ballasts $270 $120 $40
740
kWh
$15
-
kW-mo/yr
- $215 -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $225 $47 $185
3,390
kWh
$40
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $35,515 $167 $225
4,130
kWh
$55
-
kW-mo/yr
$7,020 $215 $28,000
TOTAL IMPLEMENTED $35,515 $167 $225
4,130
kWh
$55
-
kW-mo/yr
$7,020 $215 $28,000
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs