| Assessment Year | 1996 |
|---|---|
| Principal Product | Ice cream sticks |
| NAICS |
n/a
|
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
80,000
ft2
|
| Annual Production | 0
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Maine |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $86,909 | 1,203,107 |
kWh
|
$0.072 |
| Electricity Demand | $23,293 | 2,745 |
kW-mo/yr
|
$8.49 |
| Electricity Fees | $1,141 | - |
|
- |
| Fuel Oil #4 | $15,578 | 3,592 |
MMBtu
|
$4.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,318 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,555 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #4 Savings | Solid Waste (non-haz) Savings | Water Consumption Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4235: Remove or close off unneeded compressed air lines | $5,616 | $290 |
$5,616
80,305
kWh
|
- | - | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,536 | $21,778 |
$4,298
61,254
kWh
|
$1,238
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $1,575 | $3,600 |
$1,575
22,567
kWh
|
- | - | - | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,182 | $600 |
$1,182
16,999
kWh
|
- | - | - | - | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $759 | $500 |
$759
10,844
kWh
|
- | - | - | - | - | |
| 06 | 2.2511: Insulate bare equipment | $147 | $192 | - | - |
$147
-
MMBtu
|
- | - | - | |
| 07 | 3.5313: Increase amount of waste recovered for resale | $9,374 | $4,932 | - | - | - |
$2,400
-
lb
|
- | $6,974 | |
| 08 | 2.2511: Insulate bare equipment | $4,129 | $1,282 |
$2,419
34,584
kWh
|
$407
-
kW-mo/yr
|
$1,263
-
MMBtu
|
- |
$40
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $28,318 | $33,174 |
$15,849
226,553
kWh
|
$1,645
-
kW-mo/yr
|
$1,410
-
MMBtu
|
$2,400
-
lb
|
$40
-
Tgal
|
$6,974 | ||
| TOTAL IMPLEMENTED | $22,555 | $32,692 |
$10,233
146,248
kWh
|
$1,645
-
kW-mo/yr
|
$1,263
-
MMBtu
|
$2,400
-
lb
|
$40
-
Tgal
|
$6,974 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #4 Savings | Solid Waste (non-haz) Savings | Water Consumption Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs