Assessment Year | 1996 |
---|---|
Principal Product | Millwork |
NAICS |
n/a
|
SIC | 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
59,625
ft2
|
Annual Production | 20,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,512 | 712,192 |
kWh
|
$0.071 |
Electricity Demand | $18,964 | 2,328 |
kW-mo/yr
|
$8.15 |
Electricity Fees | $415 | - |
|
- |
LPG | $10,039 | 1,319 |
MMBtu
|
$7.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,518 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,518 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,017 | $11,793 |
$2,823
40,152
kWh
|
$1,194
-
kW-mo/yr
|
- | - | - | |
02 | 2.7241: Install outside air damper / economizer on hvac unit | $1,210 | $8,250 |
$1,210
17,292
kWh
|
- | - | - | - | |
03 | 2.2437: Recover waste heat from equipment | $1,212 | $930 | - | - |
$1,212
-
MMBtu
|
- | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $1,716 | - | - | - | - | - | $1,716 | |
05 | 2.8114: Change rate schedules or other changes in utility service | $1,068 | - | - | - | - | - | $1,068 | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,687 | $100 |
$1,687
24,033
kWh
|
- | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $449 | $1,000 |
$449
6,448
kWh
|
- | - | - | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $350 | $350 |
$350
7,327
kWh
|
- | - | - | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $209 | $100 |
$209
2,931
kWh
|
- | - | - | - | |
10 | 3.6192: Use a less expensive method of waste removal | $1,600 | - | - | - | - |
$1,600
-
lb
|
- | |
TOTAL RECOMMENDED | $13,518 | $22,523 |
$6,728
98,183
kWh
|
$1,194
-
kW-mo/yr
|
$1,212
-
MMBtu
|
$1,600
-
lb
|
$2,784 | ||
TOTAL IMPLEMENTED | $13,518 | $22,523 |
$6,728
98,183
kWh
|
$1,194
-
kW-mo/yr
|
$1,212
-
MMBtu
|
$1,600
-
lb
|
$2,784 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs