Assessment Year | 1995 |
---|---|
Principal Product | Modular Homes |
NAICS |
n/a
|
SIC | 2452: Prefabricated Wood Buildings and Components |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
60,700
ft2
|
Annual Production | 572
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $47,115 | 419,988 |
kWh
|
$0.11 |
LPG | $19,318 | 2,604 |
MMBtu
|
$7.42 |
Fuel Oil #2 | $3,120 | 534 |
MMBtu
|
$5.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,958 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,433 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.231: Purchase equipment instead of leasing | $5,460 | $13,000 | - | - | - | - | $5,460 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,774 | $18,027 |
$4,774
41,618
kWh
|
- | - | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $2,260 | - | - | - | - | - | $2,260 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,142 | $600 |
$1,142
16,413
kWh
|
- | - | - | - | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,031 | $5,000 |
$3,096
33,998
kWh
|
$(-1,065.0)
-
MMBtu
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $218 | $300 |
$218
3,224
kWh
|
- | - | - | - | |
07 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $13,785 | $5,380 | - | - | - |
$13,785
-
gal
|
- | |
08 | 3.5316: Contract a wood pallet recycling company | $288 | - | - | - |
$288
-
gal
|
- | - | |
TOTAL RECOMMENDED | $29,958 | $42,307 |
$9,230
95,253
kWh
|
$(-1,065.0)
-
MMBtu
|
$288
-
gal
|
$13,785
-
gal
|
$7,720 | ||
TOTAL IMPLEMENTED | $5,433 | $5,600 |
$4,238
50,411
kWh
|
$(-1,065.0)
-
MMBtu
|
- | - | $2,260 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs