Assessment Year | 1995 |
---|---|
Principal Product | Stainless Steel fabrications |
NAICS |
n/a
|
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
90,000
ft2
|
Annual Production | 2,500,000
lb
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,198 | 972,743 |
kWh
|
$0.11 |
LPG | $58,721 | 6,683 |
MMBtu
|
$8.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,261 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,826 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings | Gaseous Waste Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $3,151 | - | - | - | - | $3,151 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,438 | $420 |
$1,438
10,844
kWh
|
- | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $879 | $300 |
$879
13,482
kWh
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $511 | $1,600 |
$511
8,792
kWh
|
- | - | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $455 | - | - | - | - | $455 | |
06 | 2.2437: Recover waste heat from equipment | $435 | $930 |
$435
5,275
kWh
|
- | - | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $252 | $97 |
$252
2,931
kWh
|
- | - | - | |
08 | 2.6125: Keep equipment clean | $200 | $150 |
$200
2,052
kWh
|
- | - | - | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,940 | $300 | - | - |
$2,940
-
lb
|
- | |
10 | 3.6125: Sell combustible waste | $2,000 | - | - |
$2,000
-
lb
|
- | - | |
TOTAL RECOMMENDED | $12,261 | $3,797 |
$3,715
43,376
kWh
|
$2,000
-
lb
|
$2,940
-
lb
|
$3,606 | ||
TOTAL IMPLEMENTED | $9,826 | $2,867 |
$3,280
38,101
kWh
|
- |
$2,940
-
lb
|
$3,606 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | Gaseous Waste Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs