| Assessment Year | 1995 |
|---|---|
| Principal Product | TEXTILES |
| NAICS |
n/a
|
| SIC | 2299: Textile goods, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 40 |
| Plant Area |
58,300
ft2
|
| Annual Production | 3,000,000
lb
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Maine |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $111,561 | 1,133,353 |
kWh
|
$0.098 |
| LPG | $7,137 | 858 |
MMBtu
|
$8.32 |
| Fuel Oil #2 | $8,581 | 1,729 |
MMBtu
|
$4.96 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,752 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $31,752 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,097 | $20,385 |
$15,097
165,299
kWh
|
- | - | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $12,904 | $20,000 |
$12,424
126,026
kWh
|
$480
-
MMBtu
|
- | |
| 03 | 2.2153: Close off unneeded steam lines | $1,120 | $200 | - | - |
$1,120
-
MMBtu
|
|
| 04 | 2.2136: Install / repair insulation on steam lines | $952 | $350 | - | - |
$952
-
MMBtu
|
|
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $907 | $400 | - | - |
$907
-
MMBtu
|
|
| 06 | 2.2515: Use optimum thickness insulation | $772 | $130 |
$772
7,327
kWh
|
- | - | |
| TOTAL RECOMMENDED | $31,752 | $41,465 |
$28,293
298,652
kWh
|
$480
-
MMBtu
|
$2,979
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $31,752 | $41,465 |
$28,293
298,652
kWh
|
$480
-
MMBtu
|
$2,979
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Fuel Oil #2 Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs