Assessment Year | 1995 |
---|---|
Principal Product | Seafood |
NAICS |
n/a
|
SIC | 2091: Canned and Cured Fish and Seafoods |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
35,640
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 1,720
hrs
|
Location (State) | Maine |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $78,130 | 735,932 |
kWh
|
$0.11 |
LPG | $4,895 | 588 |
MMBtu
|
$8.32 |
Fuel Oil #2 | $4,067 | 670 |
MMBtu
|
$6.07 |
Fuel Oil #6 | $27,803 | 11,723 |
MMBtu
|
$2.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,335 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,605 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #4 Savings | Fuel Oil #6 Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,376 | $5,000 |
$2,624
25,205
kWh
|
- |
$(-248.0)
-
MMBtu
|
- | - | - | |
02 | 2.2511: Insulate bare equipment | $1,279 | $2,000 |
$1,279
12,309
kWh
|
- | - | - | - | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,195 | $3,208 |
$1,335
12,896
kWh
|
- |
$(-140.0)
-
MMBtu
|
- | - | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $1,140 | - | - | - | - | - | $1,140 | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $829 | $250 |
$829
7,913
kWh
|
- | - | - | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $667 | $825 |
$667
6,448
kWh
|
- | - | - | - | - | |
07 | 2.2521: Isolate steam lines to avoid heating air conditioned areas | $412 | $440 | - | - |
$412
-
MMBtu
|
- | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $317 | - |
$317
2,931
kWh
|
- | - | - | - | - | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $300 | $400 | - |
$300
-
MMBtu
|
- | - | - | - | |
10 | 3.4151: Minimize water usage | $6,411 | $2,650 | - | - | - | - | - |
$6,411
-
Tgal
|
|
11 | 3.4151: Minimize water usage | $5,469 | $3,812 | - | - | - | - | - |
$5,469
-
Tgal
|
|
12 | 3.4151: Minimize water usage | $1,940 | $450 | - |
$983
-
MMBtu
|
- |
$957
-
Tgal
|
- | - | |
TOTAL RECOMMENDED | $22,335 | $19,035 |
$7,051
67,702
kWh
|
$1,283
-
MMBtu
|
$24
-
MMBtu
|
$957
-
Tgal
|
$1,140 |
$11,880
-
Tgal
|
||
TOTAL IMPLEMENTED | $14,605 | $9,112 |
$2,425
23,153
kWh
|
$300
-
MMBtu
|
- | - | - |
$11,880
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #4 Savings | Fuel Oil #6 Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs