Assessment Year | 2012 |
---|---|
Principal Product | Plated parts |
NAICS | 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring |
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
128,000
ft2
|
Annual Production | 6,000,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,002 | 1,015,431 |
kWh
|
$0.11 |
Electricity Demand | $35,008 | 3,685 |
kW-mo/yr
|
$9.50 |
Electricity Fees | $4,200 | - |
|
- |
Natural Gas | $4,505 | 423 |
MMBtu
|
$10.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,954 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,429 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $5,986 | $2,000 |
$5,986
52,416
kWh
|
|
02 | 2.4226: Use / purchase optimum sized compressor | $1,443 | - |
$1,443
12,636
kWh
|
|
03 | 2.2511: Insulate bare equipment | $525 | $1,700 |
$525
4,604
kWh
|
|
TOTAL RECOMMENDED | $7,954 | $3,700 |
$7,954
69,656
kWh
|
||
TOTAL IMPLEMENTED | $7,429 | $2,000 |
$7,429
65,052
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs