| Assessment Year | 2015 |
|---|---|
| Principal Product | Assembled Systems |
| NAICS | 331110: Iron and Steel Mills and Ferroalloy Manufacturing |
| SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
46,000
ft2
|
| Annual Production | 1,500
pieces
|
| Production Hrs. Annual | 2,860
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $140,195 | 1,138,768 |
kWh
|
$0.12 |
| Electricity Demand | $11,181 | 2,781 |
kW-mo/yr
|
$4.02 |
| Electricity Fees | $9,218 | - |
|
- |
| Natural Gas | $35,600 | 2,751 |
MMBtu
|
$12.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,748 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,215 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $17,665 | $2,500 |
$14,912
124,058
kWh
|
- |
$2,753
-
MMBtu
|
|
| 02 | 2.8121: Apply for tax-free status for energy purchases | $8,215 | $500 | - | $8,215 | - | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $3,749 | $1,426 |
$1,088
7,961
kWh
|
- |
$2,661
-
MMBtu
|
|
| 04 | 2.7135: Install occupancy sensors | $406 | $980 |
$406
3,375
kWh
|
- | - | |
| 05 | 2.4224: Upgrade controls on compressors | $373 | $500 |
$373
2,421
kWh
|
- | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $340 | $300 |
$340
2,824
kWh
|
- | - | |
| TOTAL RECOMMENDED | $30,748 | $6,206 |
$17,119
140,639
kWh
|
$8,215 |
$5,414
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $8,215 | $500 | - | $8,215 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs