Assessment Year | 2009 |
---|---|
Principal Product | Overhaul and repair of gas turbine fuel nozzles |
NAICS | 811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Main |
SIC | 3511: Steam, Gas, and Hydraulic Turbines, and Turbine Generator Set Units |
Sales Range | $10 M to 50M |
# of Employees | 84 |
Plant Area |
43,000
ft2
|
Annual Production | 26,258
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $122,651 | 879,753 |
kWh
|
$0.14 |
Electricity Demand | $48,593 | 2,275 |
kW-mo/yr
|
$21.36 |
Electricity Fees | $4,700 | - |
|
- |
Natural Gas | $70,250 | 3,568 |
MMBtu
|
$19.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,864 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,288 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $7,158 | $8,683 |
$2,278
17,377
kWh
|
$4,880
-
MMBtu
|
|
02 | 2.2524: Avoid cooling of process streams or materials that must subsequently be heated | $5,780 | - |
$5,780
44,460
kWh
|
- | |
03 | 2.2437: Recover waste heat from equipment | $1,968 | $3,610 | - |
$1,968
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,508 | $300 |
$1,508
11,607
kWh
|
- | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,450 | $5,195 | - |
$1,450
-
MMBtu
|
|
TOTAL RECOMMENDED | $17,864 | $17,788 |
$9,566
73,444
kWh
|
$8,298
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,288 | $300 |
$7,288
56,067
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs