Assessment Year 2008
Principal Product Rifles and shotguns
NAICS 332994: Small Arms, Ordnance, and Ordnance Accessories Manufacturing
SIC 3484: Small Arms
Sales Range $50
M
to 100
M
# of Employees 268
Plant Area 317,000
ft2
Annual Production 151,000
pieces
Production Hrs. Annual 4,420
hrs
Location (State) Massachusetts

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $456,042 3,974,400
kWh
Electricity Demand $42,752 10,068
kW-mo/yr
Electricity Fees $2,712 -
Natural Gas $274,631 17,097
MMBtu
Fuel Oil #2 $65,772 3,829
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $49,943 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,444

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $33,014 $119,495 $30,154
262,900
kWh
$2,860
-
kW-mo/yr
- -
02 2.2427: Use waste heat from hot flue gases to preheat incoming fluids $11,407 $20,000 - - $11,407
-
MMBtu
-
03 2.1113: Reduce combustion air flow to optimum $2,058 $3,000 - - $2,058
-
MMBtu
-
04 2.7232: Replace existing hvac unit with high efficiency model $1,932 $2,500 $262
2,300
kWh
- - $1,670
-
gal
05 2.7251: Reduce air conditioning load by evaporating water from roof $1,034 $6,000 $1,034
9,105
kWh
- - -
06 2.2136: Install / repair insulation on steam lines $498 $500 - - $498
-
MMBtu
-
TOTAL RECOMMENDED $49,943 $151,495 $31,450
274,305
kWh
$2,860
-
kW-mo/yr
$13,963
-
MMBtu
$1,670
-
gal
TOTAL IMPLEMENTED $35,444 $122,495 $30,416
265,200
kWh
$2,860
-
kW-mo/yr
$498
-
MMBtu
$1,670
-
gal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs