Assessment Year | 2005 |
---|---|
Principal Product | Plastic Bags |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $50 M to 100M |
# of Employees | 220 |
Plant Area |
400,000
ft2
|
Annual Production | 85,000,000
lb
|
Production Hrs. Annual | 7,500
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,144,824 | 36,095,134 |
kWh
|
$0.059 |
Electricity Demand | $289,504 | 6,440 |
kW-mo/yr
|
$44.95 |
Natural Gas | $211,793 | 16,868 |
MMBtu
|
$12.56 |
LPG | $42,612 | 2,733 |
MMBtu
|
$15.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $121,144 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $61,366 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2622: Replace existing chiller with high efficiency model | $23,037 | $56,931 |
$21,676
411,300
kWh
|
$1,361
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,269 | $30,445 |
$9,908
188,000
kWh
|
$1,361
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,393 | $12,255 |
$6,393
121,300
kWh
|
- | - | |
04 | 2.6218: Turn off equipment when not in use | $3,100 | $3,295 |
$3,100
58,900
kWh
|
- | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,630 | $7,000 |
$1,630
31,200
kWh
|
- | - | |
06 | 2.2437: Recover waste heat from equipment | $16,603 | $3,312 | - | - |
$16,603
-
MMBtu
|
|
07 | 2.4221: Install compressor air intakes in coolest locations | $1,408 | $1,000 |
$1,257
23,900
kWh
|
$151
-
kW-mo/yr
|
- | |
08 | 2.7243: Improve air circulation with destratification fans / other methods | $29,100 | $25,000 |
$(-1,250.0)
(-24,000)
kWh
|
$(-150.0)
-
kW-mo/yr
|
$30,500
-
MMBtu
|
|
09 | 2.2511: Insulate bare equipment | $10,500 | $2,000 |
$10,500
199,700
kWh
|
- | - | |
10 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $9,818 | $6,420 |
$8,900
169,200
kWh
|
$918
-
kW-mo/yr
|
- | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,286 | $21,300 |
$6,080
115,600
kWh
|
$2,206
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $121,144 | $168,958 |
$68,194
1,295,100
kWh
|
$5,847
-
kW-mo/yr
|
$47,103
-
MMBtu
|
||
TOTAL IMPLEMENTED | $61,366 | $69,663 |
$42,333
804,100
kWh
|
$2,430
-
kW-mo/yr
|
$16,603
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs