Assessment Year | 2019 |
---|---|
Principal Product | Fiberglass tanks |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 108 |
Plant Area |
39,700
ft2
|
Annual Production | 1,658
units
|
Production Hrs. Annual | 2,966
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,285 | 783,838 |
kWh
|
$0.074 |
Electricity Demand | $14,684 | 2,964 |
kW-mo/yr
|
$4.95 |
Electricity Fees | $6,000 | - |
|
- |
TOTAL YEARLY COSTS | $78,969 | |||
RECOMMENDED SAVINGS* | $78,146 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $77,926 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $53,720 | $50,000 | - | - | - | - | - | - | $53,720 | |
02 | 2.4226: Use / purchase optimum sized compressor | $9,966 | $10,790 |
$7,866
104,600
kWh
|
$2,100
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $8,000 | $1,600 | - | - | - | $1,600 | - | $6,400 | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,720 | $4,420 |
$2,020
26,860
kWh
|
$530
-
kW-mo/yr
|
$140 | - | $30 | - | - | |
05 | 2.4322: Use or replace with energy efficient substitutes | $1,930 | $5,180 |
$1,530
20,330
kWh
|
$400
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.7145: Install skylights | $1,210 | $3,400 |
$1,210
16,140
kWh
|
- | - | - | - | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $380 | $570 |
$380
4,990
kWh
|
- | - | - | - | - | - | |
08 | 2.4314: Use synthetic lubricant | $220 | $300 |
$170
2,230
kWh
|
$50
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $78,146 | $76,260 |
$13,176
175,150
kWh
|
$3,080
-
kW-mo/yr
|
$140 | $1,600 | $30 | $6,400 | $53,720 | ||
TOTAL IMPLEMENTED | $77,926 | $75,960 |
$13,006
172,920
kWh
|
$3,030
-
kW-mo/yr
|
$140 | $1,600 | $30 | $6,400 | $53,720 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs