| Assessment Year | 2002 |
|---|---|
| Principal Product | Thermoplastic Polyurethane Film and Sheet |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 78 |
| Plant Area |
107,000
ft2
|
| Annual Production | 7,200,000
lb
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $254,930 | 6,151,680 |
kWh
|
$0.041 |
| Electricity Demand | $210,526 | 13,478 |
kW-mo/yr
|
$15.62 |
| Electricity Fees | $55,297 | - |
|
- |
| Natural Gas | $76,893 | 7,996 |
MMBtu
|
$9.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $26,598 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,216 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,554 | $9,225 |
$6,699
158,627
kWh
|
$4,855
-
kW-mo/yr
|
- | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,604 | $13,500 |
$5,659
133,995
kWh
|
$4,123
-
kW-mo/yr
|
$(-4,178.0)
-
MMBtu
|
|
| 03 | 2.7264: Interlock heating and air conditioning systems to prevent simultaneous operation | $3,778 | - |
$2,341
19,696
kWh
|
- |
$1,437
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,391 | $1,102 |
$1,966
46,512
kWh
|
$1,425
-
kW-mo/yr
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $1,289 | $1,100 |
$747
17,687
kWh
|
$542
-
kW-mo/yr
|
- | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $982 | $3,275 |
$982
23,256
kWh
|
- | - | |
| TOTAL RECOMMENDED | $26,598 | $28,202 |
$18,394
399,773
kWh
|
$10,945
-
kW-mo/yr
|
$(-2,741.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $17,216 | $14,702 |
$10,394
246,082
kWh
|
$6,822
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs