Assessment Year | 2001 |
---|---|
Principal Product | Latches |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
70,000
ft2
|
Annual Production | 9,603,500
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,248 | 1,311,841 |
kWh
|
$0.067 |
Electricity Demand | $47,803 | 3,445 |
kW-mo/yr
|
$13.88 |
Electricity Fees | $7,178 | - |
|
- |
Natural Gas | $17,563 | 3,413 |
MMBtu
|
$5.15 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,270 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,190 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $7,300 | $3,000 | - | - |
$7,300
-
MMBtu
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,900 | $8,400 |
$6,900
108,441
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,310 | $550 |
$2,310
36,342
kWh
|
- | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,760 | $5,800 |
$2,550
39,566
kWh
|
$170
-
kW-mo/yr
|
$(-960.0)
-
MMBtu
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $930 | - |
$930
14,654
kWh
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $750 | $1,250 |
$750
12,016
kWh
|
- | - | |
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $320 | $1,400 |
$390
6,155
kWh
|
$120
-
kW-mo/yr
|
$(-190.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $20,270 | $20,400 |
$13,830
217,174
kWh
|
$290
-
kW-mo/yr
|
$6,150
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,190 | $13,200 |
$10,890
171,453
kWh
|
- |
$7,300
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs