Assessment Year | 1996 |
---|---|
Principal Product | Gaskets |
NAICS |
n/a
|
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
100,000
ft2
|
Annual Production | 75,000,000
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,247 | 533,998 |
kWh
|
$0.064 |
Electricity Demand | $29,220 | 3,444 |
kW-mo/yr
|
$8.48 |
Natural Gas | $8,002 | 1,905 |
MMBtu
|
$4.20 |
Fuel Oil #2 | $43,164 | 9,782 |
MMBtu
|
$4.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,608 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,281 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $23,668 | $72,000 | - | - |
$(-12,505.0)
-
MMBtu
|
$36,173
-
MMBtu
|
- | |
02 | 2.3192: Use fossil fuel powered generator during peak demand periods | $2,604 | $5,000 |
$1,233
18,171
kWh
|
$2,861
-
kW-mo/yr
|
- |
$(-1,490.0)
-
MMBtu
|
- | |
03 | 2.2511: Insulate bare equipment | $2,340 | $4,335 |
$2,340
34,584
kWh
|
- | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $613 | $200 |
$613
11,723
kWh
|
- | - | - | - | |
05 | 3.5217: Reuse / recycle/ sell paper products | $495 | - | - | - | - | - |
$495
-
lb
|
|
06 | 2.7135: Install occupancy sensors | $472 | $770 |
$472
7,034
kWh
|
- | - | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $416 | $312 |
$416
6,155
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $30,608 | $82,617 |
$5,074
77,667
kWh
|
$2,861
-
kW-mo/yr
|
$(-12,505.0)
-
MMBtu
|
$34,683
-
MMBtu
|
$495
-
lb
|
||
TOTAL IMPLEMENTED | $24,281 | $72,200 |
$613
11,723
kWh
|
- |
$(-12,505.0)
-
MMBtu
|
$36,173
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings | Solid Waste (non-haz) Savings |