Assessment Year | 1995 |
---|---|
Principal Product | motion transfer devices |
NAICS |
n/a
|
SIC | 3568: Mechanical Power Transmission Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 229 |
Plant Area |
110,000
ft2
|
Annual Production | 35,000,000
pieces
|
Production Hrs. Annual | 6,500
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $326,997 | 2,789,566 |
kWh
|
$0.12 |
Natural Gas | $20,828 | 2,394 |
MMBtu
|
$8.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,181 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,684 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Consumption Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,934 | $44,000 |
$16,934
153,576
kWh
|
- | |
02 | 3.4114: Replace city water with recycled water via cooling tower | $4,708 | $5,000 |
$(-220.0)
(-1,172)
kWh
|
$4,928
-
Tgal
|
|
03 | 2.6225: Eliminate third shift | $4,455 | - |
$4,455
67,409
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $850 | $800 |
$850
9,379
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $750 | $1,200 |
$750
5,275
kWh
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $484 | - |
$484
7,327
kWh
|
- | |
TOTAL RECOMMENDED | $28,181 | $51,000 |
$23,253
241,794
kWh
|
$4,928
-
Tgal
|
||
TOTAL IMPLEMENTED | $17,684 | $45,200 |
$17,684
158,851
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs