Assessment Year | 1995 |
---|---|
Principal Product | Basement Doors |
NAICS |
n/a
|
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 118 |
Plant Area |
115,000
ft2
|
Annual Production | 43,000
pieces
|
Production Hrs. Annual | 2,168
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $124,090 | 905,920 |
kWh
|
$0.14 |
Fuel Oil #2 | $25,446 | 5,794 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,919 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,065 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $1,427 | - | - |
$1,427
-
MMBtu
|
|
02 | 2.7135: Install occupancy sensors | $854 | $2,191 |
$854
9,672
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $595 | $580 |
$595
6,741
kWh
|
- | |
04 | 2.7264: Interlock heating and air conditioning systems to prevent simultaneous operation | $582 | - |
$582
4,982
kWh
|
- | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $461 | - |
$461
5,275
kWh
|
- | |
TOTAL RECOMMENDED | $3,919 | $2,771 |
$2,492
26,670
kWh
|
$1,427
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,065 | $580 |
$1,638
16,998
kWh
|
$1,427
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs