Assessment Year | 1995 |
---|---|
Principal Product | textile machinery |
NAICS |
n/a
|
SIC | 3552: Textile Machinery |
Sales Range | $10 M to 50M |
# of Employees | 78 |
Plant Area |
130,000
ft2
|
Annual Production | 3
pieces
|
Production Hrs. Annual | 2,085
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,022 | 1,666,764 |
kWh
|
$0.086 |
Natural Gas | $51,380 | 6,371 |
MMBtu
|
$8.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,847 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,129 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,525 | $5,100 |
$2,525
22,274
kWh
|
- | |
02 | 2.6232: Install set-back timers | $1,718 | $150 |
$1,718
33,118
kWh
|
- | |
03 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $731 | - | - |
$731
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $475 | - |
$475
7,327
kWh
|
- | |
05 | 2.7135: Install occupancy sensors | $398 | $422 |
$398
7,327
kWh
|
- | |
TOTAL RECOMMENDED | $5,847 | $5,672 |
$5,116
70,046
kWh
|
$731
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,129 | $5,522 |
$3,398
36,928
kWh
|
$731
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs