Assessment Year | 1994 |
---|---|
Principal Product | books, calendars, brochures |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 189 |
Plant Area |
100,000
ft2
|
Annual Production | 20,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $262,487 | 3,073,271 |
kWh
|
$0.085 |
Natural Gas | $48,688 | 8,834 |
MMBtu
|
$5.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,901 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,669 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $21,512 | $16,194 | - |
$21,512
-
MMBtu
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,576 | - |
$3,576
41,911
kWh
|
- | |
03 | 2.7313: Recycle air for heating, ventilation and air conditioning | $1,905 | $629 | - |
$1,905
-
MMBtu
|
|
04 | 2.7224: Reduce space conditioning during non-working hours | $1,618 | $685 | - |
$1,618
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $1,426 | $1,789 |
$1,426
16,706
kWh
|
- | |
06 | 2.3212: Optimize plant power factor | $1,389 | $2,700 |
$1,389
-
kWh
|
- | |
07 | 2.6231: Utilize controls to operate equipment only when needed | $475 | $312 |
$475
5,569
kWh
|
- | |
TOTAL RECOMMENDED | $31,901 | $22,309 |
$6,866
64,186
kWh
|
$25,035
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,669 | $997 |
$4,051
47,480
kWh
|
$1,618
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs