| Assessment Year | 1993 |
|---|---|
| Principal Product | Indexable milling cutter |
| NAICS |
n/a
|
| SIC | 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices |
| Sales Range | $5 M to 10M |
| # of Employees | 92 |
| Plant Area |
64,635
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Vermont |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $105,625 | 1,066,823 |
kWh
|
$0.099 |
| Fuel Oil #4 | $14,973 | 3,917 |
MMBtu
|
$3.82 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,391 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,716 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $8,282 | $20,878 |
$8,282
-
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,675 | $4,811 |
$6,675
67,409
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $486 | $67 |
$486
4,982
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,948 | $180 |
$1,948
19,637
kWh
|
|
| TOTAL RECOMMENDED | $17,391 | $25,936 |
$17,391
92,028
kWh
|
||
| TOTAL IMPLEMENTED | $10,716 | $21,125 |
$10,716
24,619
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs