| Assessment Year | 1993 |
|---|---|
| Principal Product | Printed Circuit Boards |
| NAICS |
n/a
|
| SIC | 3672: Printed Circuit Boards |
| Sales Range | $10 M to 50M |
| # of Employees | 167 |
| Plant Area |
136,000
ft2
|
| Annual Production | 60
thousand feet
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $636,484 | 7,658,851 |
kWh
|
$0.083 |
| Fuel Oil #4 | $130,472 | 33,769 |
MMBtu
|
$3.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,153 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6121: Reduce hot water temperature to the minimum required | $9,079 | $2,733 | - |
$9,079
-
MMBtu
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,949 | $125 |
$1,949
23,447
kWh
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $853 | - |
$853
10,258
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $585 | $91 |
$585
7,034
kWh
|
- | |
| 05 | 2.2122: Install / repair insulation on condensate lines | $687 | $169 | - |
$687
-
MMBtu
|
|
| TOTAL RECOMMENDED | $13,153 | $3,118 |
$3,387
40,739
kWh
|
$9,766
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs