Assessment Year 1992
Principal Product VINYL SHEETING AND FILM
NAICS
n/a
SIC 2295: Coated Fabrics, Not Rubberized
Sales Range $10
M
to 50
M
# of Employees 116
Plant Area
n/a
Annual Production 21,000
thousand feet
Production Hrs. Annual 5,760
hrs
Location (State) Connecticut

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $577,279 6,085,580
kWh
Natural Gas $116,960 35,302
MMBtu
Fuel Oil #6 $44,541 16,624
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $44,383 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,358

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings LPG Savings Fuel Oil #6 Savings
01 2.1331: Burn a less expensive grade of fuel $20,512 - - $34,170
-
MMBtu
$(-13,658.0)
-
MMBtu
-
02 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $10,171 $100 $10,171
107,268
kWh
- - -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,808 $6,580 $4,808
50,703
kWh
- - -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,251 $5,020 $2,251
23,740
kWh
- - -
05 2.2122: Install / repair insulation on condensate lines $1,845 $600 - $1,263
-
MMBtu
- $582
-
MMBtu
06 2.2414: Use waste heat from hot flue gases to preheat $1,480 $2,854 - $1,014
-
MMBtu
- $466
-
MMBtu
07 2.2135: Repair and eliminate steam leaks $1,312 $300 - $950
-
MMBtu
- $362
-
MMBtu
08 2.1393: Use steam sparging or injections in place of indirect heating $742 $1,668 - $536
-
MMBtu
- $206
-
MMBtu
09 2.4312: Improve lubrication practices $750 - $750
7,913
kWh
- - -
10 2.4221: Install compressor air intakes in coolest locations $512 $77 $512
5,275
kWh
- - -
TOTAL RECOMMENDED $44,383 $17,199 $18,492
194,899
kWh
$37,933
-
MMBtu
$(-13,658.0)
-
MMBtu
$1,616
-
MMBtu
TOTAL IMPLEMENTED $20,358 $12,102 $14,979
157,971
kWh
$3,763
-
MMBtu
- $1,616
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings LPG Savings Fuel Oil #6 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs