Assessment Year | 1992 |
---|---|
Principal Product | RADIATORS,AIR SYSTEMS |
NAICS |
n/a
|
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
n/a
|
Annual Production | 1,000,000
lb
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $127,398 | 1,435,229 |
kWh
|
$0.089 |
Natural Gas | $69,965 | 11,211 |
MMBtu
|
$6.24 |
Fuel Oil #2 | $2,649 | 75,600 |
MMBtu
|
$0.035 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,322 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,382 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $822 | $528 |
$822
9,379
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $156 | - |
$156
1,758
kWh
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $494 | $319 |
$494
5,569
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,327 | $300 |
$1,327
14,947
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,405 | $3,381 |
$1,405
15,826
kWh
|
|
06 | 2.6218: Turn off equipment when not in use | $1,118 | $246 |
$1,118
12,603
kWh
|
|
TOTAL RECOMMENDED | $5,322 | $4,774 |
$5,322
60,082
kWh
|
||
TOTAL IMPLEMENTED | $3,382 | $4,000 |
$3,382
38,100
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs