Assessment Year | 1991 |
---|---|
Principal Product | INDUSTRIAL CARRIER ROLLS |
NAICS |
n/a
|
SIC | 3547: Rolling Mill Machinery and Equipment |
Sales Range | $1 M to 5M |
# of Employees | 33 |
Plant Area |
n/a
|
Annual Production | 420
pieces
|
Production Hrs. Annual | 5,460
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,356 | 788,687 |
kWh
|
$0.084 |
LPG | $17,388 | 1,529 |
MMBtu
|
$11.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,626 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,626 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $9,335 | $20,000 | - |
$9,335
-
MMBtu
|
|
02 | 2.4133: Use most efficient type of electric motors | $691 | $2,857 |
$691
8,206
kWh
|
- | |
03 | 2.7245: Use direct air supply to exhaust hoods | $5,388 | $2,800 |
$(-2,071.0)
(-24,619)
kWh
|
$7,459
-
MMBtu
|
|
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,202 | - |
$2,640
31,360
kWh
|
$(-1,438.0)
-
MMBtu
|
|
05 | 2.3212: Optimize plant power factor | $2,718 | $4,000 |
$2,718
-
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $292 | $381 |
$312
3,810
kWh
|
$(-20.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $19,626 | $30,038 |
$4,290
18,757
kWh
|
$15,336
-
MMBtu
|
||
TOTAL IMPLEMENTED | $19,626 | $30,038 |
$4,290
18,757
kWh
|
$15,336
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs