Assessment Year | 1990 |
---|---|
Principal Product | PROCESSED FILM & PHOTOS |
NAICS |
n/a
|
SIC | 2741: Miscellaneous Publishing |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 1,950
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $63,637 | 723,623 |
kWh
|
$0.088 |
LPG | $12,631 | 1,299 |
MMBtu
|
$9.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,434 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,589 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $327 | $1,000 |
$327
3,517
kWh
|
- | |
02 | 2.6232: Install set-back timers | $381 | $256 |
$381
4,103
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $195 | $100 |
$195
5,862
kWh
|
- | |
04 | 2.7314: Reduce ventilation air | $192 | $152 |
$9
-
kWh
|
$183
-
MMBtu
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $1,518 | $9,027 |
$1,518
45,721
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $567 | $657 |
$567
6,448
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,439 | $6,413 |
$1,439
15,533
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $815 | $656 |
$815
9,379
kWh
|
- | |
TOTAL RECOMMENDED | $5,434 | $18,261 |
$5,251
90,563
kWh
|
$183
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,589 | $8,234 |
$3,406
41,325
kWh
|
$183
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs