Assessment Year 1990
Principal Product WOOL AND ACRYLIC FELT
NAICS
n/a
SIC 2231: Broadwoven Fabric Mills, Wool (Including Dyeing and Finishing)
Sales Range $10
M
to 50
M
# of Employees 230
Plant Area
n/a
Annual Production 1,560,000
lb
Production Hrs. Annual 7,200
hrs
Location (State) Massachusetts

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $288,251 4,524,033
kWh
Natural Gas $474,096 94,684
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $47,161 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,894

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.4221: Install compressor air intakes in coolest locations $1,083 $426 $1,083
16,999
kWh
- -
02 2.1233: Analyze flue gas for proper air/fuel ratio $16,783 $10,500 - $16,783
-
MMBtu
-
03 2.7245: Use direct air supply to exhaust hoods $1,045 $1,198 $(-187.0)
(-2,931)
kWh
$1,232
-
MMBtu
-
04 2.2424: Use heat in flue gases to preheat products or materials $14,356 $28,350 $(-10,549.0)
(-165,592)
kWh
$24,905
-
MMBtu
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $13,894 $7,048 $14,656
230,070
kWh
- $(-762.0)
TOTAL RECOMMENDED $47,161 $47,522 $5,003
78,546
kWh
$42,920
-
MMBtu
$(-762.0)
TOTAL IMPLEMENTED $13,894 $7,048 $14,656
230,070
kWh
- $(-762.0)
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs