Assessment Year | 1990 |
---|---|
Principal Product | ETCHED METALS |
NAICS |
n/a
|
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 42 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,423
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,024 | 1,082,063 |
kWh
|
$0.077 |
Natural Gas | $21,022 | 3,367 |
MMBtu
|
$6.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,609 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,237 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $1,664 | $5,000 |
$1,664
21,688
kWh
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,372 | $5,957 |
$1,530
19,930
kWh
|
$842
-
MMBtu
|
- | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $4,848 | $500 |
$3,910
50,996
kWh
|
$938
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,333 | $9,634 |
$1,007
13,189
kWh
|
- | $326 | |
05 | 2.7221: Lower temperature during the winter season and vice-versa | $3,130 | $1,195 |
$32
1,465
kWh
|
$3,098
-
MMBtu
|
- | |
06 | 2.2514: Cover open tanks | $1,262 | $229 |
$1,262
16,413
kWh
|
- | - | |
TOTAL RECOMMENDED | $14,609 | $22,515 |
$9,405
123,681
kWh
|
$4,878
-
MMBtu
|
$326 | ||
TOTAL IMPLEMENTED | $12,237 | $16,558 |
$7,875
103,751
kWh
|
$4,036
-
MMBtu
|
$326 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs