Assessment Year | 1990 |
---|---|
Principal Product | COSMETIC JARS AND CAPS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 116 |
Plant Area |
n/a
|
Annual Production | 94,260,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $237,768 | 3,208,968 |
kWh
|
$0.074 |
Natural Gas | $63,609 | 16,557 |
MMBtu
|
$3.84 |
Fuel Oil #2 | $9,983 | 2,261 |
MMBtu
|
$4.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,008 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $518 | - |
$518
-
kWh
|
- | - | |
02 | 2.7314: Reduce ventilation air | $12,741 | $3,500 | - |
$12,741
-
MMBtu
|
- | |
03 | 2.2122: Install / repair insulation on condensate lines | $173 | $316 | - |
$173
-
MMBtu
|
- | |
04 | 2.6232: Install set-back timers | $1,410 | $657 |
$1,410
19,050
kWh
|
- | - | |
05 | 2.2511: Insulate bare equipment | $5,188 | $1,277 | - |
$5,188
-
MMBtu
|
- | |
06 | 2.7226: Use computer programs to optimize hvac performance | $6,410 | $2,620 | - |
$4,646
-
MMBtu
|
$1,764
-
MMBtu
|
|
TOTAL RECOMMENDED | $26,440 | $8,370 |
$1,928
19,050
kWh
|
$22,748
-
MMBtu
|
$1,764
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,008 | $4,554 |
$1,410
19,050
kWh
|
$9,834
-
MMBtu
|
$1,764
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs