Assessment Year | 1990 |
---|---|
Principal Product | THERMAL GRADE PAPER |
NAICS |
n/a
|
SIC | 3861: Photographic Equipment and Supplies |
Sales Range | $10 M to 50M |
# of Employees | 155 |
Plant Area |
n/a
|
Annual Production | 31,048,724
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $508,120 | 8,718,347 |
kWh
|
$0.058 |
LPG | $282,768 | 83,752 |
MMBtu
|
$3.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $136,327 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $75,114 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
---|---|---|---|---|---|---|
01 | 2.2122: Install / repair insulation on condensate lines | $388 | $649 | - |
$388
-
MMBtu
|
|
02 | 2.1213: Direct warmest air to combustion intake | $992 | $865 | - |
$992
-
MMBtu
|
|
03 | 2.3212: Optimize plant power factor | $62,064 | $80,000 |
$62,064
-
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,525 | $120 |
$6,525
111,958
kWh
|
- | |
05 | 2.6232: Install set-back timers | $6,525 | $1,524 |
$6,525
111,958
kWh
|
- | |
06 | 2.2443: Re-use or recycle hot or cold process exhaust air | $24,108 | $27,827 | - |
$24,108
-
MMBtu
|
|
07 | 2.2437: Recover waste heat from equipment | $35,725 | $19,518 | - |
$35,725
-
MMBtu
|
|
TOTAL RECOMMENDED | $136,327 | $130,503 |
$75,114
223,916
kWh
|
$61,213
-
MMBtu
|
||
TOTAL IMPLEMENTED | $75,114 | $81,644 |
$75,114
223,916
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings |