Assessment Year | 1989 |
---|---|
Principal Product | PRINTED CIRCUIT BOARDS |
NAICS |
n/a
|
SIC | 3672: Printed Circuit Boards |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 1,000
thousand feet
|
Production Hrs. Annual | 7,854
hrs
|
Location (State) | New Hampshire |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $484,016 | 7,453,107 |
kWh
|
$0.065 |
Natural Gas | $87,183 | 15,421 |
MMBtu
|
$5.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,505 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,580 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $14,558 | $10,000 |
$14,558
224,209
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,218 | - |
$1,218
18,757
kWh
|
- | |
03 | 2.6232: Install set-back timers | $228 | $195 |
$228
3,517
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,362 | $570 |
$2,362
36,342
kWh
|
- | |
05 | 2.2122: Install / repair insulation on condensate lines | $475 | $305 | - |
$475
-
MMBtu
|
|
06 | 2.4131: Size electric motors for peak operating efficiency | $2,664 | $2,700 |
$2,664
41,032
kWh
|
- | |
TOTAL RECOMMENDED | $21,505 | $13,770 |
$21,030
323,857
kWh
|
$475
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,580 | $570 |
$3,580
55,099
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs