| Assessment Year | 1988 |
|---|---|
| Principal Product | FILTRATION EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
| Sales Range | $10 M to 50M |
| # of Employees | 331 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | New Hampshire |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $677,212 | 10,063,013 |
kWh
|
$0.067 |
| Fuel Oil #2 | $68,035 | 15,960 |
MMBtu
|
$4.26 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $64,598 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $33,909 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $6,928 | $2,859 |
$2,465
36,635
kWh
|
- |
$4,463
-
MMBtu
|
|
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $7,534 | $85,000 |
$24,796
368,406
kWh
|
$(-17,262.0)
-
MMBtu
|
- | |
| 03 | 2.3212: Optimize plant power factor | $19,447 | $9,000 |
$19,447
82,649
kWh
|
- | - | |
| 04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $10,222 | $3,943 |
$18,123
269,343
kWh
|
$(-7,901.0)
-
MMBtu
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,467 | $72,797 |
$20,467
304,220
kWh
|
- | - | |
| TOTAL RECOMMENDED | $64,598 | $173,599 |
$85,298
1,061,253
kWh
|
$(-25,163.0)
-
MMBtu
|
$4,463
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $33,909 | $96,859 |
$46,708
487,690
kWh
|
$(-17,262.0)
-
MMBtu
|
$4,463
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs