| Assessment Year | 1987 |
|---|---|
| Principal Product | PRECISION GEARS |
| NAICS |
n/a
|
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 90 |
| Plant Area |
n/a
|
| Annual Production | 120,000
lb
|
| Production Hrs. Annual | 5,460
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,114 | 808,030 |
kWh
|
$0.079 |
| Natural Gas | $4,093 | 687 |
MMBtu
|
$5.96 |
| Fuel Oil #2 | $1,512 | 280 |
MMBtu
|
$5.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,560 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,218 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7226: Use computer programs to optimize hvac performance | $13,369 | $400 |
$13,369
168,523
kWh
|
|
| 02 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $263 | $350 |
$263
3,224
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $271 | $100 |
$271
3,517
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,315 | $168 |
$1,315
16,706
kWh
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $342 | - |
$342
4,396
kWh
|
|
| TOTAL RECOMMENDED | $15,560 | $1,018 |
$15,560
196,366
kWh
|
||
| TOTAL IMPLEMENTED | $15,218 | $1,018 |
$15,218
191,970
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs