Assessment Year | 1987 |
---|---|
Principal Product | HI-TEMP WIRE & CABLES |
NAICS |
n/a
|
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $5 M to 10M |
# of Employees | 55 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $166,674 | 2,152,989 |
kWh
|
$0.077 |
Fuel Oil #2 | $11,415 | 2,384 |
MMBtu
|
$4.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,319 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,952 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $712 | $100 | - |
$712
-
MMBtu
|
|
02 | 2.2511: Insulate bare equipment | $4,334 | $1,215 |
$4,334
55,979
kWh
|
- | |
03 | 2.7141: Lower light fixtures in high ceiling areas | $8,321 | $3,062 |
$8,321
107,562
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $1,619 | $400 | - |
$1,619
-
MMBtu
|
|
05 | 2.3191: Use demand controller or load shedder | $3,000 | $3,400 |
$3,000
-
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,333 | - |
$2,333
30,188
kWh
|
- | |
TOTAL RECOMMENDED | $20,319 | $8,177 |
$17,988
193,729
kWh
|
$2,331
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,952 | $400 |
$2,333
30,188
kWh
|
$1,619
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs