Assessment Year | 1986 |
---|---|
Principal Product | ZINC DIE-CAST PRODUCTS |
NAICS |
n/a
|
SIC | 3369: Nonferrous Foundries, Except Aluminum and Copper |
Sales Range | $1 M to 5M |
# of Employees | 26 |
Plant Area |
n/a
|
Annual Production | 800,000
lb
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $27,297 | 211,899 |
kWh
|
$0.13 |
Natural Gas | $38,222 | 4,879 |
MMBtu
|
$7.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,596 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,859 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $1,510 | $2,500 |
$1,510
11,723
kWh
|
- | - | |
02 | 2.2514: Cover open tanks | $157 | - | - |
$157
-
MMBtu
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $1,812 | $1,700 |
$1,812
14,068
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $566 | $109 |
$566
4,396
kWh
|
- | - | |
05 | 2.7261: Install timers and/or thermostats | $2,380 | $1,200 | - |
$2,380
-
MMBtu
|
- | |
06 | 2.7494: Install storm windows and doors | $1,206 | $1,760 | - |
$1,206
-
MMBtu
|
- | |
07 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $6,965 | - |
$(-2,303.0)
(-17,878)
kWh
|
$5,003
-
MMBtu
|
$4,265 | |
TOTAL RECOMMENDED | $14,596 | $7,269 |
$1,585
12,309
kWh
|
$8,746
-
MMBtu
|
$4,265 | ||
TOTAL IMPLEMENTED | $5,859 | $5,400 |
$3,322
25,791
kWh
|
$2,537
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs