Assessment Year | 1985 |
---|---|
Principal Product | ELECTRICAL RESISTANCE WIRE |
NAICS |
n/a
|
SIC | 3315: Steel Wiredrawing and Steel Nails and Spikes |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
n/a
|
Annual Production | 2,600,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $371,669 | 5,286,049 |
kWh
|
$0.070 |
Natural Gas | $8,858 | 968 |
MMBtu
|
$9.15 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $51,521 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $721 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $721 | $500 |
$721
10,258
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,081 | $87 |
$2,081
29,601
kWh
|
|
03 | 2.4322: Use or replace with energy efficient substitutes | $15,656 | $40,000 |
$15,656
222,743
kWh
|
|
04 | 2.6218: Turn off equipment when not in use | $33,063 | $3,200 |
$33,063
470,399
kWh
|
|
TOTAL RECOMMENDED | $51,521 | $43,787 |
$51,521
733,001
kWh
|
||
TOTAL IMPLEMENTED | $721 | $500 |
$721
10,258
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs