ITAC Assessment: GT0501
ITAC logo
ITAC Assessment: GT0501
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product Cotton/Polyester Cloth
NAICS
n/a
SIC 2211: Broadwoven Fabric Mills, Cotton
Sales Range $10
M
to 50
M
# of Employees 500
Plant Area 500,000
ft2
Annual Production 479,700
lb
Production Hrs. Annual 8,400
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $3,226,602 102,920,283
kWh
Natural Gas $104,626 35,950
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $176,680 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $95,930

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1221: Replace obsolete burners with more efficient ones $5,620 $10,000 - $5,620
-
MMBtu
02 2.1241: Reduce excessive boiler blowdown $1,760 - - $1,760
-
MMBtu
03 2.7142: Utilize higher efficiency lamps and/or ballasts $33,930 $115,900 $33,930
1,080,598
kWh
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $54,440 $20,000 $54,440
1,733,880
kWh
-
05 2.4221: Install compressor air intakes in coolest locations $21,500 $3,500 $21,500
684,642
kWh
-
06 2.4224: Upgrade controls on compressors $21,170 $30,000 $21,170
674,385
kWh
-
07 2.4133: Use most efficient type of electric motors $13,710 $65,530 $13,710
436,987
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $20,070 $81,700 $20,070
638,921
kWh
-
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $4,480 - $4,480
143,611
kWh
-
TOTAL RECOMMENDED $176,680 $326,630 $169,300
5,393,024
kWh
$7,380
-
MMBtu
TOTAL IMPLEMENTED $95,930 $224,930 $90,310
2,876,612
kWh
$5,620
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs