Assessment Year 2015
Principal Product Beverages
NAICS 311920: Coffee and Tea Manufacturing
SIC 2043: Cereal Breakfast Foods
Sales Range $50
M
to 100
M
# of Employees 95
Plant Area 140,000
ft2
Annual Production 26,600,000
pieces
Production Hrs. Annual 7,200
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $981,041 15,690,000
kWh
Electricity Demand $177,205 36,529
kW-mo/yr
Natural Gas $1,623,755 247,717
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $151,546 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $50,572

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $53,712 $100,740 $53,712
859,390
kWh
- - -
02 2.7231: Use radiant heater for spot heating $45,555 $130,520 - - $45,555
-
MMBtu
-
03 2.1233: Analyze flue gas for proper air/fuel ratio $16,058 $1,700 - - $16,126
-
MMBtu
$(-68.0)
04 2.4157: Establish a predictive maintenance program $10,550 $1,000 $12,187
194,990
kWh
$1,576
-
kW-mo/yr
- $(-3,213.0)
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,891 $599 $6,989
111,828
kWh
$902
-
kW-mo/yr
- -
06 2.2511: Insulate bare equipment $6,111 $6,377 - - $6,111
-
MMBtu
-
07 2.4151: Develop a repair/replace policy $5,821 $864 $5,876
94,013
kWh
$761
-
kW-mo/yr
- $(-816.0)
08 2.7142: Utilize higher efficiency lamps and/or ballasts $4,141 $19,874 $3,302
52,837
kWh
$839
-
kW-mo/yr
- -
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,537 - $1,362
21,799
kWh
$175
-
kW-mo/yr
- -
10 2.4239: Eliminate or reduce compressed air usage $170 $457 $151
2,412
kWh
$19
-
kW-mo/yr
- -
TOTAL RECOMMENDED $151,546 $262,131 $83,579
1,337,269
kWh
$4,272
-
kW-mo/yr
$67,792
-
MMBtu
$(-4,097.0)
TOTAL IMPLEMENTED $50,572 $30,414 $28,354
453,668
kWh
$4,078
-
kW-mo/yr
$22,237
-
MMBtu
$(-4,097.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs